{
  "HAPI": "3.2",
  "x_description": "This dataset contains 4-sec averages of the 3-dimensional Electric field vector in the inertial frame (i.e., vxB removed) in the spacecraft coordinate system (GSE), using EFW electric field data from C2_CP_EFW_L3_E and FGM magnetic field data from C2_CP_FGM_5VPS that are used to calculate the 4-sec averaged 3-dimensional magnetic field vector for the time stamps of electric field data. The spin-axis component of the electric field is calculated with assumption of E.B equals 0 and with use of 2 electric field components measured in the spin plane and three magnetic field components. This dataset also includes the magnitude and elevation angle of the magnetic field vector to estimate the quality of the spin-axis electric field component. The data are not filtered, contrary to C2_CP_EFW_L3_E3D_GSE dataset, and therefore no FILLVAL are used for small spin-axis component or elevation angle of the magnetic field vector.  Detailed quality information is provided as a 16 bit set of flags in the parameter E_bitmask__C2_CP_EFW_L3_E3D_GSE_EX. The meaning of the bits is as follows (LSB numbering starting at 0): Bit  0: Reset. Bit  1: Bad bias. Bit  2: Probe latchup. Bit  3: Low density saturation (-68V). Bit  4: Sweep (collection and dump). Bit  5: Burst dump. Bit  6: Non-standard operations (NS_OPS). Bit  7: Manual flag. Bit  8: Not used. Bit  9: Not used. Bit 10: Solar wind wake correction applied. Bit 11: Lobe wake. Bit 12: Plasmaspheric wake. Bit 13: Whisper operating. Bit 14: Saturation due to high bias current. Bit 15: Bias current DAC not responding correctly. Bit 16: Saturation due to probe shadow.",
  "cadence": "PT4.000000S",
  "parameters": [
    {
      "type": "isotime",
      "units": "UTC",
      "name": "time_tags",
      "label": "Universal Time",
      "fill": null
    },
    {
      "type": "double",
      "name": "E_Vec_xyz_GSE",
      "description": "Electric Field",
      "label": "Electric Field",
      "units": "mV/m",
      "fill": "-1e+31",
      "size": [
        3
      ]
    },
    {
      "type": "double",
      "name": "B_Vec_xyz_GSE",
      "description": "Magnetic Field",
      "label": "Magnetic Field",
      "units": "nT",
      "fill": "-1e+31",
      "size": [
        3
      ]
    },
    {
      "type": "double",
      "name": "delta_Ez_GSE",
      "description": "Error of electric field (GSE)",
      "label": "Error of electric field (GSE)",
      "units": "mV/m",
      "fill": "-1e+31"
    },
    {
      "type": "integer",
      "name": "E_bitmask",
      "description": "Electric field measurement quality bitmask",
      "label": "Electric field measurement quality bitmask",
      "units": null,
      "fill": "0"
    },
    {
      "type": "integer",
      "name": "E_quality",
      "description": "Electric field measurement quality flag (4=best)",
      "label": "Electric field measurement quality flag (4=best)",
      "units": null,
      "fill": "0"
    },
    {
      "type": "double",
      "name": "B_z_abs_GSE",
      "description": "Abs value of B-field z-component",
      "label": "Abs value of B-field z-component",
      "units": "nT",
      "fill": "-1e+31"
    },
    {
      "type": "double",
      "name": "B_alpha_GSE",
      "description": "Angle of magnetic field relative to spin plane",
      "label": "Angle of magnetic field relative to spin plane",
      "units": "Degrees",
      "fill": "-1e+31"
    },
    {
      "type": "integer",
      "name": "B_number",
      "description": "Number of B-field values used to calculate 4s average",
      "label": "Number of B-field values used to calculate 4s average",
      "units": null,
      "fill": "0"
    },
    {
      "type": "double",
      "name": "E_sigma",
      "description": "Electric field standard deviation",
      "label": "Electric field standard deviation",
      "units": "mV/m",
      "fill": "-1000000000.000"
    }
  ],
  "startDate": "2000-12-02T00:00Z",
  "stopDate": "2022-09-01T00:00Z",
  "x_tap_url": "https://csa.esac.esa.int/csa-sl-tap/data?retrieval_type=HEADER&DATASET_ID=C2_CP_EFW_L3_E3D_GSE_EX&FORCEPACK=false",
  "x_tap_data_url": "https://csa.esac.esa.int/csa-sl-tap/data?RETRIEVAL_TYPE=product&RETRIEVAL_ACCESS=streamed&DATASET_ID=C2_CP_EFW_L3_E3D_GSE_EX&START_DATE=2022-09-01T00:00Z&END_DATE=2022-09-01T00:00Z",
  "status": {
    "code": 1200,
    "message": "OK"
  },
  "x_LastUpdate": "2026-04-12T15:10:21Z"
}