{
  "HAPI": "3.2",
  "x_description": "This dataset contains mode settings for the RAPID instrument onboard Cluster SC2 Ordered in 11 different integer values, which give information about IIMS and IES instrument modes as well as IIMS high voltages A new record occurs only when at least one of the values changes The time range is given for each record",
  "cadence": "PT4.000000S",
  "parameters": [
    {
      "type": "isotime",
      "x_type": "ISO_TIME_RANGE",
      "units": "UTC",
      "name": "Time_range",
      "description": "Validity time range of a specified caveat",
      "label": "Universal Time Range",
      "length": 25,
      "fill": null
    },
    {
      "type": "isotime",
      "x_type": "ISO_TIME_RANGE",
      "units": "UTC",
      "name": "Time_range_stop",
      "length": 25,
      "fill": null
    },
    {
      "type": "integer",
      "name": "Telemetry",
      "description": "Telemetry mode indicator: 0=NM; 1=BM1; 2=BM2; 3=BM3; 4=NM3",
      "label": "Telemetry mode",
      "units": null,
      "fill": "-255"
    },
    {
      "type": "integer",
      "name": "IIMS_Mode_A",
      "description": "IIMS A flag: 0=HV off; 1=serial; 2=parallel; 4=test data; 5=dump data",
      "label": "IIMS mode A",
      "units": null,
      "fill": "-255"
    },
    {
      "type": "integer",
      "name": "IIMS_Mode_B",
      "description": "IIMS B flag: 0=cold S/B; 1=hot S/B; 2=HV on; 3=Defl on; 4=HV operating level; 5=ENA",
      "label": "IIMS mode B",
      "units": null,
      "fill": "-255"
    },
    {
      "type": "integer",
      "name": "IIMS_Trigger",
      "description": "Trigger mode: 0=E+T; 1=E+(D*T); 2=E*D*T; 3=E*T; 4=E; 5=T",
      "label": "IIMS trigger mode",
      "units": null,
      "fill": "-255"
    },
    {
      "type": "integer",
      "name": "Start_Volt",
      "description": "Voltage on the MCP that gives the time-of-flight start signal",
      "label": "Start Voltage",
      "units": "V",
      "fill": "-255"
    },
    {
      "type": "integer",
      "name": "Stop_Volt",
      "description": "Voltage on the MCP that gives the time-of-flight stop signal",
      "label": "Stop Voltage",
      "units": "V",
      "fill": "-255"
    },
    {
      "type": "integer",
      "name": "Def_Volt",
      "description": "Voltage on the ion deflector plates, for neutral particle mode",
      "label": "Deflection Voltage",
      "units": "V",
      "fill": "-255"
    },
    {
      "type": "integer",
      "name": "IES_Mode_L",
      "description": "IES L flag: 0=measuring; 1=in-flight test",
      "label": "IES mode L",
      "units": null,
      "fill": "-255"
    },
    {
      "type": "integer",
      "name": "IES_Mode_M",
      "description": "IES M flag: 1=normal; 3=histogram test data",
      "label": "IES mode M",
      "units": null,
      "fill": "-255"
    },
    {
      "type": "integer",
      "name": "IES_Int_Time",
      "description": "IES integration time: accummulation time for single measurement",
      "label": "IES integration time",
      "units": "us",
      "fill": "-255"
    },
    {
      "type": "integer",
      "name": "IES_Autosw",
      "description": "IES autoswitching: 0=OFF; 1=ON (int. time switches automatically)",
      "label": "IES autoswitching",
      "units": null,
      "fill": "-255"
    }
  ],
  "startDate": "2000-12-01T00:00Z",
  "stopDate": "2024-02-02T00:00Z",
  "x_tap_url": "https://csa.esac.esa.int/csa-sl-tap/data?retrieval_type=HEADER&DATASET_ID=C2_CP_RAP_DSETTINGS&FORCEPACK=false",
  "sampleStartDate": "2022-03-31T10:00Z",
  "sampleStopDate": "2022-04-01T00:00Z",
  "x_tap_data_url": "https://csa.esac.esa.int/csa-sl-tap/data?RETRIEVAL_TYPE=product&RETRIEVAL_ACCESS=streamed&DATASET_ID=C2_CP_RAP_DSETTINGS&START_DATE=2022-03-31T10:00:00.000Z&END_DATE=2022-04-01T00:00:00.000Z",
  "status": {
    "code": 1200,
    "message": "OK"
  },
  "x_LastUpdate": "2026-04-12T15:13:50Z"
}